Control for PUR reverse osmosis systems including TDS measurement
Control for PUR reverse osmosis systems including TDS measurement.
The control unit processes the input signals from the high-pressure and low-pressure sensors and switches the booster pump and the solenoid valves of your PUR reverse osmosis system depending on the pressure condition.
Per button press "Washing", the control ensures a 45-second rinse, which is displayed via a timer.
The TDS measuring probe is inserted into a 1/4" quick connector. The following adapter is perfectly suitable for this: T-Adapter 1/4" x 1/4" x 1/4" hose angle adapter with safety clips - EAN: 4260303252797. The measuring range is 01 - 99 ppm. If exceeded, "OUA" is displayed.
Additionally, the following operating states are displayed on the individual 7-segment display:
- The system is in production mode
- Flush: A flush is being performed
- The system is filled and ready for operation
- Lack Blinkt: Low pressure switch has detected too low an input pressure
- Device is shutting down due to overheating
This control with integrated TDS measurement is used as standard in the following PUR reverse osmosis systems:
- PUR Booster 5 Stages 600 GPD Direct Flow Tankless Reverse Osmosis System - EAN: 4260303254760
- PUR Smart PRO 800 GPD reverse osmosis system brushless tankless - EAN: 4260303255552
Included in the delivery:
- Control with TDS measuring probe
- Bracket
You receive a controller with a fixed TDS measuring probe.